CYPEFIRE Hydraulic Systems allows the sizing and design of hydraulic fire extinguishing networks using sprinklers and fire hose reels (FHR) in accordance with different predefined codes, as well as designing installations by creating customised configurations for calculating other codes or for personal technical purposes.
País |
Code |
CP 52 : 2004 (Singapore Standard - Code of practice for automatic fire sprinkler system) |
|
EN 12845:2016 (Fixed firefighting systems - Automatic sprinkler systems - Design, installation and maintenance) |
|
NFPA® 13 (National Fire Protection Association) |
|
Customisable codes |
CYPEFIRE Hydraulic Systems allows users to design, analyse and size a fire extinguishing installation composed of sprinklers. The program carries out the necessary hydraulic calculations and checks to ensure the requirements of the NFPA®13 standard are met. These include:
CYPEFIRE Hydraulic Systems uses the EPANET 2 calculation engine (developed by Water Supply and Water Resources Division National Risk Management Research Laboratory) to carry out the hydraulic calculations necessary for designing sprinkler networks and fire hose reels (FHR).
EPANET provides accurate calculation results, which are suitable for compliance with any of the codes available in the application or those that are manually entered by the user.
EPANET allows calculation equations to be selected for solving load loss equations. By default CYPEFIRE Hydraulic Systems calculates according to the Hazen-Williams equation but can be solved using the Darcy-Weisbach equation, which is required for certain cases in the NFPA 13 code.
CYPEFIRE Hydraulic Systems allows the following types of sprinklers to be used:
As well as their typology, the application allows all operation-related parameters to be modified (orientation in the installation, K factor, sprinkler thread size and response speed). Sprinklers can be defined either within the program or imported from the CYPEFIRE Hydraulic Systems predefined sprinkler library.
Introducing and designing sprinkler networks requires careful consideration due to the geometrical checks that must be carried out to comply with each of the codes. To facilitate and speed up this process, CYPEFIRE Hydraulic Systems offers different ways of introducing sprinkler networks.
CYPEFIRE Hydraulic Systems also allows Fire Hose Reels to be designed and analysed, either as an analysis method providing a fixed flow that oversizes the sprinkler system or as another element in the system that must comply with the minimum pressure and flow conditions necessary according to the code applied.
CYPEFIRE Hydraulic Systems provides two ways of calculating load losses produced by the singular elements (accessories and valves) of sprinkler networks and/or fire hose reels.
Analysing and designing an automatic sprinkler system can be quite complex. All the hydraulic calculation requirements that comply with the various applicable codes make selecting the size of the pipes to be used one of the most complex tasks when designing the system.
The sizing tool can be configured by the user in “General options > Sizing rules”. From this panel, it is possible to edit the diameters to be used for sizing and the maximum number of sprinklers that each diameter can feed until the next diameter is reached.
If no changes are to be made to the default data, the " Sizing " tool will start the diameter selection process and then the hydraulic analysis. This selection and hydraulic analysis process will end if no errors are found when comparing the results obtained with the code requirements. Otherwise, the process shall be repeated until valid diameters are selected to comply with the applied code.
Designing the hangers to keep pipe installations fixed to a building is a task that is easily solved with CYPEFIRE Hydraulic Systems. From the application, the predefined hanger catalogue can be used or a new catalogue can be entered manually.
Once the type of hanger to be used has been selected, users must consider the distribution of the hangers throughout the system so that the weight is evenly distributed.
The NFPA 13 code includes a number of checks for designing seismic supports. These checks have been implemented in CYPEFIRE Hydraulic Systems so that this type of element can be correctly introduced wherever it is required (the west coast of North America is the area covered by NFPA 13).
To design this system, the application has the following element catalogues:
The application can introduce the different seismic brace assemblies that will reduce movement produced by earthquakes with these three elements:
In the “Bill of quantities” tab, users can find tools for generating and managing the system's quantities and cost estimations. Here, users can extract the model’s bill of quantities and generate real items using that information. This process is carried out by means of a corresponding system between the elements measured on the analysis model and the concepts of the bill of quantities (mapping). This equivalence is stored in a local or network file so that it can be progressively expanded and used in future projects.
To facilitate entering prices for the job, it is possible to import both complete databases and individual concepts from cost databases that have been developed in accordance with the FIEBDC-3 standard (.bc3).
The quantities and cost estimations documents can be extracted in several reports (Quantities, Cost breakdown structure, Detailed priced bills of quantities, BoQ summary) exportable in HTML, DOCX, PDF, RTF and TXT formats.
Once the sprinkler systems and hydraulic analysis have been defined, CYPEFIRE Hydraulic Systems carries out the checks corresponding to the NFPA®13 standard and generates the justification reports and required drawings.
Once the hydraulic design and checks have been carried out on the system, CYPEFIRE Hydraulic Systems can provide an on-screen display of any errors or information on the results of the hydraulic design and the design of the sprinkler system.
CYPEFIRE Hydraulic Systems generates the justification files that are necessary to meet the requirements of the NFPA®13 standard, such as:
The program provides detailed drawings of the installation of the sprinkler system. It provides a tool that allows users to configure the floor plans that will be represented in the drawings.
Users can print the drawings directly or export them to different formats (DWG, DXF, PDF, XPS).
In order for CYPEFIRE Hydraulic Systems to be able to carry out the aforementioned specifications, the user license must include the "CYPEFIRE Hydraulic Systems" permission.